Search results for "Coefficient of Variation"

showing 10 items of 77 documents

Heterogeneous Indicators of Cognitive Performance and Performance Variability Across the Lifespan

2020

Reaction time (RT) and RT variability are core components of cognitive performance that can be captured through brief and easy-to-administer tasks of simple RT and choice RT. The current study aims to describe age-related differences in cognitive performance, toward better characterizing normative performance across the lifespan. We examined mean and variability of response times on a simple RT and choice RT tasks in a large and diverse web-based sample (10,060 visitors to TestMyBrain.org). We also examined lifespan-related differences in response time variability using multiple different approaches (raw variability, mean scaled variability, and mean residualized variability). These analyse…

0301 basic medicineAgingdigital neuropsychologyCoefficient of variationCognitive NeuroscienceSample (statistics)Standard deviationweblcsh:RC321-571Single measure03 medical and health sciences0302 clinical medicineStatisticsEffects of sleep deprivation on cognitive performanceSegmented regressionlcsh:Neurosciences. Biological psychiatry. Neuropsychiatrycognitive performanceMathematicsvariabilityBrief Research ReportMiddle age030104 developmental biologyMetric (unit)030217 neurology & neurosurgerylifespanNeuroscienceFrontiers in Aging Neuroscience
researchProduct

Comparative measurement of collagen bundle orientation by Fourier analysis and semiquantitative evaluation: reliability and agreement in Masson's tri…

2017

Summary Measurement of collagen bundle orientation in histopathological samples is a widely used and useful technique in many research and clinical scenarios. Fourier analysis is the preferred method for performing this measurement, but the most appropriate staining and microscopy technique remains unclear. Some authors advocate the use of Haematoxylin-Eosin (H&E) and confocal microscopy, but there are no studies comparing this technique with other classical collagen stainings. In our study, 46 human skin samples were collected, processed for histological analysis and stained with Masson's trichrome, Picrosirius red and H&E. Five microphotographs of the reticular dermis were taken with a 20…

0301 basic medicinePolarized light microscopyHistologyMaterials science030102 biochemistry & molecular biologyCoefficient of variationAnalytical chemistryMagnificationPathology and Forensic MedicineStainingMasson's trichrome stain03 medical and health sciencessymbols.namesake030104 developmental biologyTrichromeFourier analysisMicroscopysymbolsBiomedical engineeringJournal of Microscopy
researchProduct

The Use of Frozen-Thawed Platelet-Derived Phospholipids as a Confirmatory Test for the Diagnosis of Lupus Anticoagulants. Comparison with Two Commerc…

1999

Lupus anticoagulants (LAs) belong to acquired circulating anticoagulants interfering with phospholipid-dependent coagulation tests. Owing to the remarkable variability among patients, SSC guidelines recommend more than one test to detect and confirm the presence of LAs. However, this is an expensive procedure and greatly raises the work load of the laboratory. A standardised platelet-derived phospholipid preparation was obtained and platelet neutralisation (PNP) procedures with APTT and DRVVT reagents were performed on plasmas from 16 patients with LAs and from 41 control subjects. In comparisons, STAclot-PNP and DVVconfirm clotting assays were conducted. PNP by using APTT or DRVVT reagents…

AdultBlood PlateletsMaleinorganic chemicalsAdolescentmedicine.drug_classCoefficient of variationCoagulation testingHumansMedicineheterocyclic compoundsPlateletPhospholipidsAgedBlood coagulation testCryopreservationLupus anticoagulantChromatographySystemic lupus erythematosusbusiness.industryAnticoagulantHematologyMiddle Agedmedicine.diseaseControl subjectsenzymes and coenzymes (carbohydrates)Freeze DryingLupus Coagulation InhibitorImmunologyFemaleBlood Coagulation TestsbusinessThrombosis Research
researchProduct

Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisiti…

1998

A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint…

AdultCartilage ArticularMalePatellar cartilageMaterials sciencemedicine.diagnostic_testCoefficient of variationCartilageReproducibility of ResultsMagnetic resonance imagingPatellaRepeatabilityImage EnhancementMagnetic Resonance ImagingNuclear magnetic resonancemedicine.anatomical_structureHealthy volunteersImage Processing Computer-AssistedmedicineHumansFemaleOrthopedics and Sports MedicineAcquisition timeDigital data processingBiomedical engineeringJournal of Orthopaedic Research
researchProduct

Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)

1996

The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surfaces (3D MR-CCM) has been developed for cartilage thickness measurements. Eight cadaveric knee-joint specimens and six volunteers were imaged using a fat-suppressed gradient-echo sequence at a resolution of 2 x 0.31 x 0.31 mm3. Cartilage volumes and topographical thickness maps were obtained and compared with those derived from anatomical sections by image analysis. The deviation …

AdultCartilage ArticularMalemusculoskeletal diseasesAccuracy and precisionMaterials scienceKnee JointCoefficient of variationKnee JointmedicineHumansRadiology Nuclear Medicine and imagingJoint (geology)AgedAged 80 and overObserver Variationmedicine.diagnostic_testCartilageReproducibility of ResultsMagnetic resonance imagingAnatomyMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureFemalePatellaCadaveric spasmBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Validation of a mechanical method for measuring skin thickness: relation to age, body mass index, skin thickness determined by ultrasound, and bone m…

2009

In a number of endocrine disorders, typical changes in skin thickness can be observed which make measurement of skin thickness interesting in this field. A newly developed mechanical method for measuring skin thickness is presented. Using a digital measuring screw on the dorsum of the hand with a defined measuring force of 10 newton and a resulting tissue compression of 1500 mm Hg, highly reproducible results were obtained (mean coefficient of variation 2.56%). In 129 women, 37 to 78 years old, body mass index < 30 kg/m2, there was no significant relation between body mass index and skin fold thickness. A negative correlation between skin fold thickness and age (r = 0.37, p < 0.001) was det…

AdultMaleAgingBone densityEndocrinology Diabetes and MetabolismCoefficient of variationBone and BonesHypopituitarismBody Mass IndexEndocrinologyForearmDermisSkin foldBone DensityInternal MedicinemedicineHumansAgedSkinUltrasonographyBone mineralintegumentary systemChemistrybusiness.industryUltrasoundReproducibility of ResultsGeneral MedicineAnatomyMiddle AgedSkinfold Thicknessmedicine.anatomical_structureFemaleCollagenbusinessBody mass indexBiomedical engineeringExperimental and clinical endocrinologydiabetes : official journal, German Society of Endocrinology [and] German Diabetes Association
researchProduct

Understanding the effect of window length and overlap for assessing sEMG in dynamic fatiguing contractions: A non-linear dimensionality reduction and…

2020

The Short-Time Fourier transform (STFT) is a helpful tool to identify muscle fatigue with clinical and sports applications. However, the choice of STFT parameters may affect the estimation of myoelectrical manifestations of fatigue. Here, we determine the effect of window length and overlap selections on the frequency slope and the coefficient of variation from EMG spectrum features in fatiguing contractions. We also determine whether STFT parameters affect the relationship between frequency slopes and task failure. Eighty-eight healthy adult men performed one-leg heel-rise until exhaustion. A factorial design with a window length of 50, 100, 250, 500, and 1000 ms with 0, 25, 50, 75, and 90…

AdultMaleCoefficient of variation0206 medical engineeringBiomedical EngineeringBiophysics02 engineering and technologyElectromyography03 medical and health sciencessymbols.namesake0302 clinical medicineIsometric ContractionmedicineCluster AnalysisHumansOrthopedics and Sports MedicineMuscle SkeletalCluster analysisMathematicsFourier AnalysisMuscle fatiguemedicine.diagnostic_testElectromyographybusiness.industryDimensionality reductionRehabilitationShort-time Fourier transformPattern recognitionFunction (mathematics)020601 biomedical engineeringFourier transformMuscle FatiguesymbolsArtificial intelligencebusiness030217 neurology & neurosurgeryMuscle ContractionJournal of Biomechanics
researchProduct

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Intra and intersession repeatability and reliability of the S-Plate® pressure platform.

2017

Abstract Aim The aim of this study was to assess the repeatability and reliability of the S-Plate® pressure platform in a group of healthy subjects. Material and methods Forty subjects, free from physical conditions that would affect normal gait, walked along a five-meter corridor while data were recorded from the pressure platform. A total of 10 steps (five each side) were obtained as well as five static trials; the same measurements were repeated one week later. Peak and mean plantar pressures and contact area were recorded for both dynamic and static trials. Additionally, weight supported on each limb was documented during static trials. To assess intrasession and intersession repeatabil…

AdultMaleIntraclass correlationCoefficient of variationBiophysicsWalking03 medical and health sciences0302 clinical medicinePlate pressurePressureHumansOrthopedics and Sports MedicineGaitReliability (statistics)MathematicsOrthodonticsFootPlantar pressureRehabilitationHealthy subjectsReproducibility of Results030229 sport sciencesRepeatabilityBiomechanical PhenomenaNormal gaitExercise TestFemale030217 neurology & neurosurgeryGaitposture
researchProduct

Multislice multiecho T2* cardiac magnetic resonance for the detection of heterogeneous myocardial iron distribution in thalassaemia patients

2009

The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV), was compared with that of a surrogate data set, to determine whether the inhomogeneous segme…

AdultMaleIron OverloadIronCoefficient of variationMyocardial ironBasal (phylogenetics)medicineHumansDistribution (pharmacology)Radiology Nuclear Medicine and imagingMultisliceIn patientSpectroscopyChemistrybusiness.industryMyocardiumMagnetic Resonance Imagingmedicine.anatomical_structureVentricleThalassemiaMolecular MedicineFemaleCardiac magnetic resonanceNuclear medicinebusinessNMR in Biomedicine
researchProduct